Vladyslav Pereverzyev

Updating exocad to a new version without losing settings

How to update exocad to a new version without losing settings: check the license first, install next to the old version, move libraries and test before use.

Every exocad release brings new tools and every update in a busy lab carries the same fear: losing libraries, material settings and the small adjustments that make the software fit the lab. A careful update avoids that. This post explains how to update exocad to a new version without losing settings, in the order I follow when I update workstations for labs.

Check the license before installing

Installing a version does not mean the license covers it. During setup exocad checks whether the license on the dongle is authorized for that version and a perpetual license without a current update entitlement may not run the new release. A Flex subscription includes updates. Ask the reseller which versions the dongle covers and see exocad licenses: perpetual vs Flex for the difference.

Check the hardware requirements of the new release too. exocad updates its requirements over time, for example on the supported Windows versions, and a workstation that ran the old version may need an operating system update first (see exocad system requirements).

Install next to the old version

exocad releases install as their own program folder, so the old version can stay on the computer while the new one is tested. Keep it. If a library, a machine export or a material behaves differently in the new release, the lab keeps working with the old version until it is solved.

Before installing, make a copy of the old program folder, at least the library folder and the configuration files. It takes a few minutes and makes every later step reversible.

Move libraries and settings

The project folders created by DentalDB hold the cases and the new version opens them. Libraries and local settings live in the program folder of each version, so they need to move:

  • implant libraries, model creator analogs and other third-party libraries, installed again from the current versions supplied by the component makers where possible;
  • local material configurations, if the lab uses its own instead of those distributed through dentalshare;
  • the lab’s design parameters, such as cement gap and minimum thickness per material;
  • machine and printer export settings.

Install libraries with the program closed and remove outdated versions so nobody picks the wrong one. The folders are listed in exocad implant library installation.

Test before production

Open a few finished cases of the indications the lab makes most often, design one of each again and send it to the mill or printer. Compare the result with the old version: cement gap, thickness, implant connection and export. Only then switch the team to the new version.

Shortcuts and workflow steps can change between releases. A short session with the team on what changed saves days of searching and the exocad keyboard shortcuts post is worth checking against the new version. If the new version refuses to start, the cause is often the license, covered in exocad license and dongle errors.

Sources

Frequently asked questions

Do I lose my cases when I update exocad?

Cases are stored in the project folders created by DentalDB, separate from the program files and a new version opens them. What needs attention are the libraries, material settings and personal parameters stored in the program folder of the old version.

Can I keep the old exocad version installed?

Yes and I recommend it until the new version has been tested on real cases. If something does not work, the lab keeps producing with the old version while the problem is solved.

Is every exocad update free?

It depends on the license. A Flex subscription includes updates, while a perpetual license runs the versions it is licensed for, and newer versions require an update entitlement from the reseller. Check this before installing.