Injection technique index: printing the models and the clear key
Printing the models for the injection technique index and making the clear silicone key: resin, base, block-out, tray, injection holes and the usual errors.
The silicone index decides how much of the wax-up reaches the patient. A good design on a poor model, or a good model with a torn or thin index, gives excess composite, open margins and a lot of finishing at the chair. This post is for labs and clinics that print the models and make the clear index for the injection technique and covers the model, the silicone and the errors that show up most often.
The model comes first
The index copies the model exactly, defects included. Before printing, the merged wax-up model should be closed, with a stable base and blocked-out areas where the silicone would lock in. The design side is described in the post on the composite injection technique in exocad.
For printing:
- Use a model resin calibrated on the printer in use. A model that is slightly too large or too small changes how the index sits in the mouth.
- Print with an orientation that keeps the labial surfaces free of supports. Support marks there are copied into the index and then into the composite.
- Post-cure fully and let the model cool before making the index. A warm or undercured model can deform under the silicone.
- Remove any resin residue in the interdental spaces. Residue becomes a bump in the composite.
The posts on resin calibration and on printing errors after post-curing cover the printing side in detail.
The clear silicone
The index is made with a transparent, rigid silicone made for this use, so the composite can be cured through it. The material’s instructions give the mixing, the working time and the setting time. A few points help on every brand.
- Use a tray that leaves a few millimeters of silicone all around the teeth. A thin index bends during injection and the shape changes.
- Some labs make a printed custom tray for the index, which uses less silicone and keeps the thickness even.
- Avoid bubbles on the labial surfaces by applying the silicone slowly from one side.
- Let it set fully on the model before removing it.
Injection holes and venting
Each tooth needs an opening where the composite goes in. The dentist usually decides the position, often incisal or labial, at a point that lets the material fill the whole space while air escapes. If the lab makes the holes, the position and diameter should be agreed with the clinician, because they depend on the syringe tip and on the order of injection.
Trimming and checking the index
The index is trimmed so it seats firmly on the teeth and on part of the gingiva, without covering more soft tissue than needed. Before delivery, seat it on the model and look through it. Any gap between the index and the teeth, a torn edge or a bubble on a labial surface is a reason to make it again.
Common errors
| Error | What happens at the chair | Prevention |
|---|---|---|
| Support marks on labial surfaces | Marks in the composite | Different print orientation |
| Undercured or warm model | Index slightly distorted | Full post-curing, cool model |
| Thin index | Index bends, shape changes | Proper tray, even thickness |
| No block-out in deep embrasures | Index tears on removal | Block-out on the model |
| Wrong model used (two-layer cases) | Wrong layer thickness | Clear names on each model |
For the two-layer version, where the first index is made on the reduced model and the second on the full one, see two-layer injection.
Labs that do not print in-house, or want models from a calibrated workflow, can order them through the 3D printing service.
Frequently asked questions
Which silicone is used for the index?
A transparent, rigid silicone made for this purpose, so the composite can be cured through it. Opaque putty does not work, because the light cannot reach the composite.
Can the index be printed instead of made in silicone?
Some clinicians use printed keys, but most work with clear silicone, which is flexible enough to come off over the contacts and rigid enough to keep the shape. A printed key needs a different design and is a separate workflow.
Where are the injection holes made?
Usually on the incisal or labial side of each tooth, at a point where the composite can fill the whole space and air can escape. The dentist decides the position, since it also depends on how they inject.
Who makes the index, the lab or the clinic?
Both are common. Some clinics receive the printed model and make the index themselves, others prefer the lab to deliver the finished index with the model.